Filler plate for Stab-lok Federal Pioneer circuit breakers. For use in present design of Stab-lok enclosures, except 400A. Will also fit previous design using 1/2" metal KO's. Consists of 1 strip of 4 - 1/2" plastic fillers suitable for 4 NC poles or 2 NA poles. CSA approved.
|
4/8 circuit 100 amp loadcentre. Capacity: 4 full mode circuits ( 1 " ) or 8 half mode circuits ( 1/2 " ). Combination mount. 1 phase; 3 wire 240V AC max.
|
Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
|
|
|
|
|
|
|
|
|
|
|
|
|
NON-COMBINATIONS Main lugs/non-combination indoor. 1 phase, 3 wire. 120/240V AC, 10,000 A/C. 1 per carton. (Uses QO breaker from Square D). For use in garages or any other out buildings requiring a separate panel such as pool sheds. Panel would be fed from a feeder breaker in the main entrance panel in the house.
|
Used as an add-on load center, connected to the service entrance loadcentre when spaces for more circuits are needed. Expandable loadcentre capacity with the use of tandem breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian Square D QO breakers.
|
4/8 circuit 100 amp loadcentre. Capacity: 4 full mode circuits ( 1 " ) or 8 half mode circuits ( 1/2 " ). Combination mount. 1 phase; 3 wire 240V AC max.
|
|
|
|
|
|
|
|
|
|
|
|
|
60 amp Homeline main breaker loadcentre with 12 spaces, 24 circuits maximum. Each is equipped with a factory installed main circuit breaker, which serves as the main disconnect to turn off power to the loadcentre, as well as to protect the load center from an overload or short circuit. Dimension: 17.92 H x 14.25 W x 3.75 D.
|
Main lug indoor load center, 100 amp, 6 space/12 circuit. NEMA type 1 enclosure. Single phase, 3 wire, solid neutral. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
|
100 amp QO main breaker only loadcentre with 16 spaces, 32 circuits maximum. Dimension: 18 H x 14.25 W x 3.75 D
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Used as an add-on load center, connected to the service entrance loadcentre when spaces for more circuits are needed. Expandable loadcentre capacity with the use of tandem breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian Square D QO breakers.
|
Used as an add-on load center, connected to the service entrance loadcentre when spaces for more circuits are needed. Expandable loadcentre capacity with the use of tandem breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian Square D QO breakers.
|
|
|
|
|
|
|
|
|
|
|
|
|
COMBINATION Ideal for use as Service Entrance Panel. 1 phase, 3 wire. Main breaker compartment can be sealed. Main breaker can be locked. Main wire size CV/AL #4-2/0. NOTE: Main Breaker is included.
|
Combines a service entrance loadcentre with a selection of breakers. Designed to accept the plug-on (pigtail less) combination arc fault circuit breakers. Circuit breakers connect directly to the neutral bar of the loadcentre, eliminating the need to attached a separate neutral wire to the neutral bar. Fully distributed neutral bar accepts either pigtail or pigtail less arc fault breaker or ground fault breaker.
|
Combines a service entrance loadcentre with a selection of breakers. Designed to accept the plug-on (pigtail less) combination arc fault circuit breakers. Circuit breakers connect directly to the neutral bar of the loadcentre, eliminating the need to attached a separate neutral wire to the neutral bar. Fully distributed neutral bar accepts either pigtail or pigtail less arc fault breaker or ground fault breaker.
|
|
|
|
|
|
|
|
|
|
|
|
|
For indoor or outdoor applications. Includes a Homeline painted, zinc-coated steel outdoor enclosure and an installed 2 pole, 50 amp ground fault circuit interrupter. Top hinged cover can be padlocked. Protects 120V and 240V loads against ground and overcurrent faults. Single phase, 3 wire with ground. 10,000 amp short circuit current interrupting rating. CSA certified for indoor or outdoor applications.
|
Combines a service entrance main breaker loadcenter and a selection of QO circuit breakers. Ready to be installed as a replacement for an older fuse box or as an upgrade. 1 phase, 3 wire, 120/240VAC. Breakers included: 10 - 1 pole 15 amp, 3 - 2 pole 15 amp, 1 - 2 pole 30 amp, 1 - 2 pole 40 amp. Combination flush/surface cover with door included. Factory installed bolt on main breaker with straight in wiring. Tin plated copper bus bars. Accepts aluminum or copper conductors. CSA approved for vertical, horizontal or inverted mounting,
|
|
|
|
|
|
|
|
|
|
|
|
Combines a service entrance main breaker loadcenter and a selection of QO circuit breakers. Ready to be installed as a replacement for an older fuse box or as an upgrade. 1 phase, 3 wire, 120/240VAC. Breakers included: 10 - 1 pole 15 amp, 3 - 2 pole 15 amp, 1 - 2 pole 30 amp, 1 - 2 pole 40 amp. Combination flush/surface cover with door included. Factory installed bolt on main breaker with straight in wiring. Tin plated copper bus bars. Accepts aluminum or copper conductors. CSA approved for vertical, horizontal or inverted mounting,
|
|
|