Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS
We found 85 results matching your criteria.
Choose a sub category:
CIRCUIT BREAKERS - SNGL POLE CIRCUIT BREAKERS - DBL POLE CIRCUIT BREAKERS - ARC FAULT
CIRCUIT BREAKERS - GFCI FUSES-CARTRIDGE/LINKS/ADAPTER FUSES-PLUG/ADAPTERS
Sort By:
Page of 2
PLG FUSE TM DLY 20A 125V      PLG FUSE TM DLY 15A 125V      PLG FUSE TM DLY 25A 125V
Leviton Plug Fuse, 125 V, 20 A, D, Glass Body Leviton Plug Fuse, 125 V, 15 A, D, Glass Body Leviton Plug Fuse, 125 V, 25 A, D, Glass Body
FUSE GLS P RATED 25A 125V 1/PK FUSE GLS P RATED 20A 125V 1/PK FUSE GLS P RATED 15A 125V 1/PK
Leviton Plug Fuse, 125 V, 25 A, P, Glass Body Leviton Plug Fuse, 125 V, 20 A, P, Glass Body Leviton Plug Fuse, 125 V, 15 A, P, Glass Body
FUSE GLS P RATED 30A 125V 1/PK FUS CRTG 15A 250V 1/PK        FUS CRTG 30A 250V 1/PK
Leviton Plug Fuse, 125 V, 30 A, P, Glass Body Leviton Fuse, 250 V, 15 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length Leviton Fuse, 250 V, 30 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length
FUS CRTG 15A 600V 1/PK        PLG FUSE TM DLY 15A 125V      PLG FUSE TM DLY 30A 125V
Leviton Fuse, 600 V, 15 A, Cartridge Fuse, 0.81 in Diameter, 5 in Length Leviton Plug Fuse, 125 V, 15 A, D, Glass Body Leviton Plug Fuse, 125 V, 30 A, D, Glass Body
PLG FUSE TM DLY 20A 125V      FUSE GLS P RATED 15A 125V 2/PK FUSE GLS P RATED 25A 125V 2/PK
Leviton Plug Fuse, 125 V, 20 A, D, Glass Body Leviton Plug Fuse, 125 V, 15 A, P, Glass Body Leviton Plug Fuse, 125 V, 25 A, P, Glass Body
FUSE GLS P RATED 20A 125V 2/PK FUSE GLS P RATED 30A 125V 2/PK FUS CRTG 50A 250V 1/BLK
Leviton Plug Fuse, 125 V, 20 A, P, Glass Body Leviton Plug Fuse, 125 V, 30 A, P, Glass Body Leviton Fuse, 250 V, 50 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length
FUSE CRTG 2IN 30A 250V        FUSE CRTG 2IN 20A 250V        FUSE CRTG 2IN 15A 250V
Leviton Fuse, 250 V, 30 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length Leviton Fuse, 250 V, 20 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length Leviton Fuse, 250 V, 15 A, Cartridge Fuse, Type D, 2-5/8 in Diameter, 3-3/4 in Length
FUS CRTG 40A 250V 1/PK        FUS CRTG 60A 250V 1/PK        FUS CRTG 100A 250V 1/PK
Leviton Fuse, 250 V, 40 A, Cartridge Fuse, 0.81 in Diameter, 3 in Length Leviton Fuse, 250 V, 60 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length Leviton Fuse, 250 V, 100 A, Cartridge Fuse, 2-5/8 in Diameter, 3-3/4 in Length, One Time Cartridge
BR115 15A SINGLE POLE CIRCUIT Homeline Square D CHOM120CP GFCI Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker
Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters (GFCI). Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 20 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 15 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating
Homeline Square D CHOM Standard Circuit Breaker BQL15 15A SINGLE POLE CIRCUIT BQL20 20A SINGLE POLE CIRCUIT
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 30 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw Cutler-Hammer Circuit Breaker, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw
Homeline Square D CHOM Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker BRKR CIRC 30A BLK 120V
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 20 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating, Suitable for: Air Conditioning, Heating and Refrigeration Non-interchangeable trip. 120 VAC, 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL listed, HACR rated. 15 and 20 A UL listed for frequent switching applications, 120 VAC fluorescent lighting. 1 in per pole.
Homeline Square D CHOMT Tandem Circuit Breaker Homeline Square D CHOMT Tandem Circuit Breaker Federal Pioneer Stab-Lok NC Standard Circuit Breaker
Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel.
Federal Pioneer Stab-Lok NC Standard Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker BR215 15A 2POLE CIRCUIT BREAKE
Square D Circuit Breaker, NC, 120 V, 20 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 12 to 2 AWG Wire, Lug Terminal, 1 Spaces, Plug Mounting, Red, Dimensions: 1/2 in Thick, 40 deg C Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 40 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 8 to 2, 8 to 2 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating Eaton type BR plug-in breakers in the standard 1 in per pole molded case and can be used as main and/or branch disconnect devices, all are CSA and UL listed, typical ampacity range for BR breakers is 15 through 125 A.
Homeline Square D CHOM Standard Circuit Breaker BR230 30A 2POLE CIRCUIT BREAKE BRKR CIRC 40A 30A USE NO8 WIRE
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 30 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, Trip Sensitivity: 6 mA, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3 in H, 104 deg F Operating, Suitable for: Air Conditioning, Heating and Refrigeration Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters (GFCI). Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel.
BRKR CIRC 15A 240V BLK        Federal Pioneer Stab-Lok NC Standard Circuit Breaker BRKR CIRC 2 POLE 20A 240V
THQP breakers are a smaller, smarter solution for today's cost and quality-conscious contractors and homeowners. Half the width of standard breakers, they allow use of smaller load centers and for maximum savings of space and money. GE is the only manufacturer that gives you this cost advantage without sacrificing flexibility. THQP breakers are one-half the width of standard GE breakers but identical in design. Square D Stab-lok Circuit Breaker, Mini, 120 VAC, 30 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 9 AWG Wire, Screw Terminal, Plug Mounting, Dimensions: 3 in L x 0.5 in W x 3.4 in H, 40 deg C Operating Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total).
BRKR CIRC BLK 15A 120V        Qwik Open Square D QO Tandem Circuit Breaker BRKR CIRC 2 POLE 15A 240V
Siemens Circuit Breaker, QT, 120 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Frame Type: EQ, Frame Size: 1/2 in, Trip Type: Thermal Magnetic, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug-In Mounting, Dimensions: 3 in L x 1 in W x 3 in H, Operating Temperature: 40 deg C QO (plug-on) and QOB (bolt-on) one-, two- and three-pole thermal-magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. Plug-on QO circuit breakers are for use in QO load centers, NQ and NQOD panelboards, OEM mounting bases and Speed-D? switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQO and NQOD panelboards. Siemens Circuit Breaker, 120/240 V, 15 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Frame Type: QP, Frame Size: 2 in, Trip Type: Thermal Magnetic, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug-In Mounting, Dimensions: 3 in L x 3 in W x 2 in H, Operating Temperature: 40 deg C
BRKR CIRC 2 POLE 30A 240V     BRKR CIRC 50A 120/240V 2 POLE QBH15 15A SINGLE POLE CIRCUIT
Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Molded case with non-interchangeable trip. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. UL listed. HACR rated. 120/240 VAC; 10,000 AIR. 1 in per pole (2 in total). Eaton Circuit Breaker, QBH, 120 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 10, 12 to 10 AWG, Number of Spaces: 1, Dimensions: 2-3/8 in L x 1 in W x 2-9/10 in H, Operating Temperature: 40 deg C
BRKR CIRC BLK 20A 2 SNGL POLES QBH20 20A SINGLE POLE CIRCUIT Federal Pioneer Stab-Lok NC Standard Circuit Breaker
Non-interchangeable trip. For retrofit use on I-T-E load centers built prior to 1965. 120/240 VAC. 1 in per duplex. Cutler-Hammer Circuit Breaker, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Quick-Break, Quick-Make Actuator, Internal Common Trip, 12 to 10, 14 to 10 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 3-1/2 in L x 3 in W x 1 in H Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel.
Federal Pioneer Stab-Lok NC Standard Circuit Breaker BREAKER CIRC BOLT ON 15A 2POLE Homeline CHOMT1515215CP Quad Tandem Circuit Breaker
Square D Stab-lok Circuit Breaker, Mini, 120/240 VAC, 15 A, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 6 AWG Wire, Screw Terminal, Plug Mounting, White, Dimensions: 3 in L x 1 in W x 3.4 in H Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 2 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 2 in H, Includes: Captive Line Screw Square D Homeline Circuit Breaker, Mini, Quad, 120/240 VAC, 15 A, 1 ph, 3 Pole, 10 kA Interrupt, Common Trip, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 2 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 2 in W x 3.13 in H, 104 deg F Operating
BREAKER BOLT-ON 2P 40 AMP     BREAKER BOLT-ON 2P 50 AMP     BREAKER BOLT-ON 2P 60 AMP
Eaton Replacement Classic Circuit Breaker, Type BQL, 120/240 VAC, 40 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Standard, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 3.1 in L x 3 in W x 2 in H, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Eaton Replacement Classic Circuit Breaker, Type BQL, 120/240 VAC, 50 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Standard, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 5 in L x 3 in W x 2 in H, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw Eaton Replacement Classic Circuit Breaker, Type BQL, 120/240 VAC, 60 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Long Time, Instantaneous, Standard, Wire Size: 8 to 2/0 AWG, Terminal Type: Bolt-On, Dimensions: 5 in L x 3 in W x 2 in H, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw