Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - SNGL POLE
We found 19 results matching your criteria.
Sort By:
Page of 1
BR115 15A SINGLE POLE CIRCUIT Homeline Square D CHOM120CP GFCI Circuit Breaker Homeline Square D CHOM Standard Circuit Breaker
Eaton's residential BR circuit breakers are used in load centers, panelboards or similar devices. They are made for a wide range of applications and include BR 1 in circuit breakers and accessories for BR-style load centers, arc fault circuit interrupters (AFCI) and ground fault circuit interrupters (GFCI). Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 20 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 15 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating
Homeline Square D CHOM Standard Circuit Breaker BQL15 15A SINGLE POLE CIRCUIT BRKR CIRC 30A BLK 120V
Square D Homeline Circuit Breaker, Mini, Standard, 120/240 VAC, 30 A, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Black, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Cutler-Hammer Circuit Breaker, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 8, 14 to 8 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 5 in L x 3 in W x 1 in H, Includes: Captive Line Screw Non-interchangeable trip. 120 VAC, 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL listed, HACR rated. 15 and 20 A UL listed for frequent switching applications, 120 VAC fluorescent lighting. 1 in per pole.
Homeline Square D CHOMT Tandem Circuit Breaker Homeline Square D CHOMT Tandem Circuit Breaker Federal Pioneer Stab-Lok NC Standard Circuit Breaker
Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 15 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Square D Homeline Circuit Breaker, Mini, Tandem, 120/240 VAC, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, 14 to 8, 14 to 8 AWG Wire, Screw Clamp Terminal, 1 Spaces, Plug Mounting, Dimensions: 3 in L x 1 in W x 3 in H, 104 deg F Operating Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel.
Federal Pioneer Stab-Lok NC Standard Circuit Breaker BRKR CIRC BLK 15A 120V        Federal Pioneer Stab-Lok NC Standard Circuit Breaker
Square D Circuit Breaker, NC, 120 V, 20 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 12 to 2 AWG Wire, Lug Terminal, 1 Spaces, Plug Mounting, Red, Dimensions: 1/2 in Thick, 40 deg C Operating Siemens Circuit Breaker, QT, 120 V, 15 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Frame Type: EQ, Frame Size: 1/2 in, Trip Type: Thermal Magnetic, Wire Size: 14 to 6 AWG, Terminal Type: Lug, Plug-In Mounting, Dimensions: 3 in L x 1 in W x 3 in H, Operating Temperature: 40 deg C Square D Stab-lok Circuit Breaker, Mini, 120 VAC, 30 A, 1 Pole, 10 kA Interrupt, Magnetic, Thermal Actuator, 14 to 9 AWG Wire, Screw Terminal, Plug Mounting, Dimensions: 3 in L x 0.5 in W x 3.4 in H, 40 deg C Operating
Qwik Open Square D QO Tandem Circuit Breaker QBH15 15A SINGLE POLE CIRCUIT QBH20 20A SINGLE POLE CIRCUIT
QO (plug-on) and QOB (bolt-on) one-, two- and three-pole thermal-magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. Plug-on QO circuit breakers are for use in QO load centers, NQ and NQOD panelboards, OEM mounting bases and Speed-D? switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQO and NQOD panelboards. Eaton Circuit Breaker, QBH, 120 V, 15 A, Number of Poles: 1, Interrupt Rating: 10 kA, Wire Size: 14 to 10, 12 to 10 AWG, Number of Spaces: 1, Dimensions: 2-3/8 in L x 1 in W x 2-9/10 in H, Operating Temperature: 40 deg C Cutler-Hammer Circuit Breaker, 120 V, 20 A, 1 ph, 1 Pole, 10 kA Interrupt, Quick-Break, Quick-Make Actuator, Internal Common Trip, 12 to 10, 14 to 10 AWG Wire, Bolt-On, Lug Terminal, Dimensions: 3-1/2 in L x 3 in W x 1 in H
BRKR CIRC BLK 20A 2 SNGL POLES BRKR CIRC 40A 30A USE NO8 WIRE BREAKER QUAD BOLT-ON 2-1P 15A
Non-interchangeable trip. For retrofit use on I-T-E load centers built prior to 1965. 120/240 VAC. 1 in per duplex. Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 in wide per pole, allows for the reduction of the size and weight of the loadcenter. These breakers are CSA approved to work only in federal pioneer branded residential panel. Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw
BREAKER QUAD BOLT-ON 2-1P 20A
Eaton Replacement Classic Circuit Breaker, Quad Type BQL, 120/240 VAC, 15 to 20 A, Number of Phases: 1, Number of Poles: 4, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Independent, Wire Size: 14 to 4 AWG, Terminal Type: Bolt-On, Dimensions: 2 in W, Suitable for: Commander QL/QM and Cutler-Hammer QM/QL Panels, Includes: Captive Line Screw